V2000-c Rfid Access Control User Manual __full__ File

Press 0000 + # . (Note: This clears all cards and PINs but retains the master code). Setting the Door Release Interlocking Time

Card only, Public PIN only, Private PIN only, Card + PIN Current Draw: Active current < 100mA; Idle current < 40mA Relay Output Load: Max 3A

The V2000-C is a robust, standalone RFID access control keypad designed for secure and reliable entry management. This comprehensive manual covers everything from technical specifications to step-by-step programming commands, wiring diagrams, and troubleshooting procedures. Technical Specifications Specification 12V DC ± 10% User Capacity 1,000 to 2,000 users (variant dependent) Card Read Distance 3 – 6 cm Compatible Card Type EM 125kHz (ID) or Mifare 13.56MHz (IC) Active Current Idle Current 25 ± 5 mA Lock Output Load Alarm Output Load Operating Temperature -45°C to 60°C Adjustable Relay Time 0 – 99 seconds Wiring Diagram and Terminal Pinout

: Verify if your lock is Fail-Safe (NC) or Fail-Secure (NO). Ensure the common wire runs through the COM terminal. If using a heavy-duty magnetic lock, power it using an independent access control power box rather than drawing directly from the keypad loop. Issue 3: The keypresses do not register V2000-c Rfid Access Control User Manual

The V2000-C RFID access control system is a compact, 2,000-user device praised for stable performance, though users often find its programming manual complex. It supports multiple entry modes, including card-only, PIN-only, or card-and-PIN combinations. Detailed information and user experiences with the device can be found on JustAnswer .

1,000 to 2,000 users (depending on the specific firmware version) Card Reading Distance: 3–8 cm

| Key | Function | Programming Steps | | :--- | :--- | :--- | | | Change System Password | Press 1 → Enter 5-digit new password (e.g., 88888) → Device beeps to confirm | | 2 | Add User (Card OR PIN) | Press 2 → Enter 4-digit User ID → Present Card OR enter 6-digit PIN → Device beeps | | 0 | Add User (Card AND PIN) | Press 0 → Enter 4-digit User ID → Present Card → Enter 6-digit PIN → Device beeps | | 3 | Delete User | Present Card OR enter 4-digit User ID of target user → Device confirms deletion | | # | Exit Programming Mode | Press # to return to normal standby state after finishing settings | Press 0000 + #

Understanding the technical limits ensures safe installation and reliable long-term operation. 12V DC ± 10%

| Error Symptom | Probable Cause | Solution | | :--- | :--- | :--- | | | Blown fuse on power supply or reverse polarity. | Check PSU, measure voltage at terminals 1 & 2 (must be 10-14V DC). | | Card beeps but lock doesn’t open | Lock wired to wrong relay (NO vs NC). | Swap lock wire from NO to COM or NC to COM. | | Lock opens for 1 second then closes | Insufficient power supply amperage (lock surge). | Upgrade to 12V DC 5A PSU. Add a capacitor across lock power. | | Continuous alarm after door closes | Door contact sensor (SEN) stuck or misaligned. | Check reed switch gap (<10mm). Set 16 0 # to disable temporarily. | | “Error” beep (two short beeps) | Command syntax error or user not found. | Re-enter command slowly. Use 14 to verify user exists. | | Master code not accepted | Someone changed it, or keypad is faulty. | Perform emergency reset (jumper method). | | RFID range is <1cm | Interference from metal or voltage drop. | Mount on non-metallic spacer. Check 12V at reader (terminal 2 & 10). |

⚠️ Change the default Master Code immediately during installation to prevent unauthorized configurations. Changing the Master Code Enter Programming Mode ( * + Master Code + # ). Press 0 . Enter your New 6-Digit Master Code and press # . Re-enter the New 6-Digit Master Code and press # . User Management If using a heavy-duty magnetic lock, power it

All user data (cards, PIN codes, system settings) is stored in non-volatile memory. The device retains all information during power outages without requiring a backup battery.

Connect a standard normally open push button between the PUSH and GND terminals. 3. Programming and Configuration Guide

: Save this new password in a secure location. If forgotten, perform factory initialization to reset to 12345 .