Slowly open the and close the Bypass Valve . The home is now supplied through the water softener. Initial Testing and Salt Loading

Run a 1/2" high-pressure hose from the drain outlet on the softener to a standpipe or a waste pipe. There must be an "air gap" at the discharge point to prevent back-siphonage.

Once installed, use a total hardness test kit. Your water should now register as "0" or "trace" hardness. If the water remains hard, check that the bypass valve is closed and the inlet/outlet valves are fully open. harvey hv3 water softener installation manual free

Are you tired of dealing with hard water in your home? Look no further than the Harvey HV3 water softener. This popular water softener model is known for its effectiveness in removing minerals that cause water to be hard, leaving you with soft, clean water for drinking, washing, and other household uses.

Check the cabinet weekly. Replace the salt blocks when they have dissolved down to approximately one-third of their original height. Never let the unit run completely out of salt, or hard water will bypass the resin tanks. Slowly open the and close the Bypass Valve

Choose a location near the rising main (main water supply entry). Ensure there is adequate space for:

Harvey has discontinued the HV3, but the installation process is nearly identical to the and HV4 . If you absolutely cannot locate the HV3 PDF, download the HV4 manual – plumbing and programming steps are 90% the same. There must be an "air gap" at the

Before cutting into your home's rising main, verify that your installation site meets the essential parameters required by Harvey Water Softeners :

Slowly open the to the softener, allowing water to fill the twin tanks gradually.

The Harvey HV3 is a popular, compact, non-electric twin-tank water softener designed to fit neatly under kitchen sinks. Because it runs purely on water pressure, installing it requires plumbing knowledge but no electrical wiring.