Daikin Brc4c160 Manual
A: While this specific remote is for a single indoor unit, Daikin offers other BRC remotes (like the BRC4C82) that can control up to 16 indoor units simultaneously. The BRC4C160's primary role is to control the single unit it is installed with.
Automatically switches between heating and cooling based on the room temperature. 2. Essential Functions & Buttons
Use the temperature arrows to change the code until the indoor unit emits a double beep.
If you tell me what specific you are seeing, or if you need instructions for a different model , I can help you find the right information.
Common Code Example : indicates an abnormal resistance level in the indoor heat thermistor. Safety Precautions Daikin Brc4c160 Manual
Adjusts the louver swing or fixes the angle.
Attach the holder with screws to the wall and hang the remote on the holder. Place it where signals can reach the indoor unit's receiver freely.
If you need help resolving a specific error code, programming a unique schedule, or configuring the controller for a multi-zone system, please let me know. To help me provide the most relevant information, tell me: What (if any) is flashing on your screen? What model number is your indoor air conditioning unit? Are you trying to program a specific timer setting ? Share public link
button cycles through Auto, Cooling, Heating, Fan Only, and Dry (Dehumidification) modes. Fan Speed Control A: While this specific remote is for a
selector button to cycle through Dry, Cool, Fan, or Heat (depending on your specific system type). Temperature Adjustment buttons. The range is typically between : Adjust the airflow strength (High, Medium, Low) using the Airflow Direction : Press the
The Daikin BRC4C160 is a robust, reliable controller when understood correctly. The frustration rarely comes from the hardware, but from the lack of access to the settings hierarchy described in the manual. If you are a facility manager, keep a laminated copy of the "Error Code" page near the unit. If you are a homeowner, remember the golden rule:
Remove the batteries if the remote will not be used for more than a month to prevent acid leaks.
Press once to start the system (indicated by the operation lamp) and again to stop. Temperature Adjustment: Common Code Example : indicates an abnormal resistance
Ensure the unit is powered on at the circuit breaker.
: Adjust airflow rates (e.g., High, Low, or Quiet) using the Fan Speed Control button.
While the official source is best, you may also find manuals on third-party documentation sites. However, exercise caution and verify the document's authenticity before use.
| Error Code | Meaning | Likely Cause | | :--- | :--- | :--- | | | Communication Error | The indoor unit cannot communicate with the outdoor unit. | | U0 / UO | Low Refrigerant / System Undercharged | The system is low on refrigerant, often due to a leak. | | A1 | Indoor Unit PCB Malfunction | The main circuit board of the indoor unit has a fault. | | A3 | Drain Level / Drainage System Error | There is a problem with the condensate drain pump or a blocked drain pipe, causing the water level to rise. | | A5 / A6 | Protection Control / Fan Motor Error | A5 indicates a system protection is active. A6 indicates a problem with the indoor fan motor. | | C4 | Liquid Pipe Thermistor Error | The thermistor (temperature sensor) on the liquid pipe is faulty. | | C5 | Gas Pipe Thermistor Error | The thermistor on the gas pipe is faulty. | | C9 | Suction Air Thermistor Error | The thermistor that measures the incoming room air temperature is faulty. | | F3 | Power Supply / Electric Circuit Error | General error related to the power supply or electrical circuit. | | L0 | Inverter System Error | There is a malfunction within the inverter system that controls the compressor. |